2009年9月9日水曜日

XTI=99の場合はあり得ない結果になった


*BeginSpec*IF: (.778,.1) (.82,.2) (.882,.5) (.93,1) (.9935,2) (1.1160,5)*JC: (0,11.280E-12) (.1,10.673E-12) (.2,10.296E-12) (.5,9.5720E-12) (1,8.8309E-12) (2,7.9208E-12) (5,6.5523E-12) (10,5.4826E-12) (20,4.4622E-12)*JC: (50,3.4881E-12) (100,2.7849E-12)*RL:*RB: Vz=0 Iz=0 Zz=0*RR: Trr=356.00E-9 Ifwd=.2 Irev=.2 Rl=50*EndSpec
*BeginTrace*IF: 1,0,.4,1.2000,1,3,0,0,-1 (27)*JC: 0,1,0,100,1,3,0,0,-1 (27)*RL: 0,0,1,100,1,3,0,0,-1 (27)*RB: 0,1,100.00E-6,1,1,3,0,0,-1 (27)*RR: 0,0,-5.0000E-9,20.000E-9,1,3,0,0,-1 (27)*EndTrace
*BeginParam*IS=132.34E-9 (10.000E-21,.1,1)*N=2.2168 (.2,5,1)*RS=21.907E-3 (1.0000E-6,100,1)*IKF=24.247 (0,1.0000E3,1)*XTI=99 (-100,100,1)*EG=1.1100 (.1,5.5100,0)*CJO=11.075E-12 (10.000E-21,1.0000E-3,1)*M=.27938 (.1,10,1)*VJ=.82645 (.3905,10,1)*FC=.5 (1.0000E-3,10,0)*ISR=0 (10.000E-21,.1,1)*NR=2 (.5,5,0)*BV=400 (.1,1.0000E6,1)*IBV=10.000E-6 (1.0000E-9,10,1)*TT=513.60E-9 (100.00E-18,1.0000E-3,1)*EndParam
*DEVICE=TVR1G,D
* TVR1G D model* updated using Model Editor release 16.0.0 on 09/09/09 at 16:23* The Model Editor is a PSpice product..MODEL TVR1G D+ IS=132.34E-9+ N=2.2168+ RS=21.907E-3+ IKF=24.247+ XTI=99+ CJO=11.075E-12+ M=.27938+ VJ=.82645+ BV=400+ IBV=10.000E-6+ TT=513.60E-9

上記はスパイスモデルの情報です。逆回復時間が常温の30-50倍になり、現実とあり得ない結果になった。
という事は、常温の3倍にしたい場合、XTIのパラメータ値を逆回復特性シミュレーションのアプローチより、決定する必要があると思う。
ユーザーは殆ど、過渡解析を行うからだ。
次に、シミュレーションを繰り返し、このアプローチからXTIを決定する。